Technical Information
Application Examples
These articles provide examples of product use case, application, and various methods and techniques such as in pneumatic circuits.
Title | Size | Download | |
---|---|---|---|
Models with Flexible Robotic Cables | - | - | |
Useful Knowledge About Safety Design Essentials 2: Safe Block |
- | - | |
Useful Knowledge About Safety Design Essentials 1: Pilot Controlled Check Valve |
- | - | |
Reference Document in Selecting an Air Cylinder | - | - | |
Usage Example of Tube Dryers (E4041) | - | - | |
Conversion table for atmospheric pressure dew point(frost point) from volume fraction(water concentration) / absolute humidity(vapor density) / relative humidity (E4041) |
- | - | |
Features of Linear Orifice Type Shock Absorbers (SP110) | - | - | |
Use Example 2: Use Example of Mini Guide Sliders (C161) | - | - | |
Use Example 1: Use Example of Jig Cylinders with Guide (C162) | - | - | |
Application Example 29: Multi-point Positioning Labeling Machine to Workpieces with Different Height (No.1041) |
- | - | |
Application Example 28: Point Trace Function Eliminating Defectives and Palletizing (No. 1040) |
- | - | |
Application Example 27: Regulators How to Utilize High Relief Regulators 2 (No.1039) |
2-1 Use Example | - | - |
2-2 Use Example | - | - | |
Application Example 26: P & P Units Conveyance of Bearings |
- | - | |
Application Example 25: Regulators How to Utilize High Relief Regulators 1 (No.1037) |
1-1 | - | - |
1-2 | - | - | |
1-3 | - | - | |
Application Example: Extra Item Non-contact Conveyor Machine (No.1036) |
- | - | |
Application Example 24: Two-axis Units Washing Machine for Glass Substrate (No.1035) |
- | - | |
Application Example 23: Palletizing Soldering Machine with Three-axis Control Lead Frame (No.1034) |
- | - | |
Application Example 22: Parts Sorting Change of the Origin Position in a Conveyed Position (No.1033) |
- | - | |
Application Example 21: Palletizing Function IC Conveyance:
Two-axis Integrated Type and Two-axis Separated Type (No.1032) |
- | - | |
Application Example 20: P & P (Vacuum Pads) Glass Conveyance (No.1031) |
- | - | |
Application Example 19: P & P Rotating-axis Specification, Drum Processing Machine (No.1030) |
- | - | |
Application Example 18: P & P Packing Machine for Medicine Cases (No.1029) |
- | - | |
Application Example 17: Multi-point Positioning Taping Machine for Cathode-ray Tubes (No.1028) |
- | - | |
Application Example 16: Three-axis Units Shoe Sole Processing Machine (No.1027) |
- | - | |
Application Example 15: Multi-point Positioning by Single-axis Robots Tray Feeder of a Food Machine (No.1026) |
- | - | |
Application Example 14: Conveyor Machine by Single-axis Robots P & P After Detecting Different-sized Workpieces (No.1025) |
- | - | |
Application Example 13: Electric Actuators / Multi-point Positioning Squeezing Process of Genonema (No.1024) |
- | - | |
Application Example 12: Electric Actuators / Conveyor / Vertical Pallet Conveyance of Curry Cubes (No.1023) |
- | - | |
Application Example 11: Electric Actuators / Conveyor / Horizontal Loading Machine for Gear Processing (No.1022) |
- | - | |
Application Example 10: Rodless Cylinders Pin Inserting Machine (No.1021) |
- | - | |
Application Example 9: Rodless Cylinders Workpiece Conveyor Machine (No.1020) |
- | - | |
Application Example 8: Rodless Cylinders Elevator Type Conveyor Machine (No.1019) |
- | - | |
Application Example 7: Rodless Cylinders Pallet Shifter (No.1018) |
- | - | |
Application Example 6: Rodless Cylinders Pusher (No.1017) |
- | - | |
Application Example 5: Rodless Cylinders Product Storing Machine (No.1016) |
- | - | |
Application Example 4: Parts Inserting Machine (No.1014) | - | - | |
Air Hands Series 2 (No.1013) | - | - | |
Application Example 2: Air Hands Series 1 (No.1012) | - | - | |
All Pneumatic Control Circuits: Part 2 (No.1011) | - | - | |
Selecting a Pneumatic Equipment 2: Basics in Selecting a Rotary Actuato (No.1010) |
- | - | |
Application Example 1: Pick and Place Equipment (No.1009) | - | - | |
All Pneumatic Control Circuits: Part 1 (No.1008) | - | - | |
Selecting a Pneumatic Equipment 1: Basics in Selecting a Rotary Actuator (No.1007) |
- | - | |
How to Perform a Cylinder Air Leakage Test (No.1006) | - | - | |
Operating Circuit of a Multiple Position Air Cylinder (No.1005) | - | - | |
Differential Pressure Control Circuit of an Air Cylinder (No.1004) | - | - | |
What is ANR? (No.1003) | - | - | |
Series or Parallel Connections with Sensor Switches (No.1002) | - | - | |
Selecting Sensor Switches (No.1001) | - | - |
Product Q&A
These buttons are quick links to product categories.
Conformity List for European Standards
Koganei will assist you to achieve CE marking compliance declaration.
1. What is CE Marking?
The CE marking is a mandatory European marking for certain product groups to indicate conformity with the essential health and safety requirements set out in European Directives. Formerly, the Member States of the European Union set their own national legislation and standard in order to guarantee the product quality and safety. However, the existence of all the different national legislation was a barrier to the aim of the EU in realizing one Single Market. In such circumstances, the European CE certification procedure was set up to harmonize all varying national regulations as well as to enhance the safety of products.
In order to affix the CE marking to a product, the manufacturer must make a compliance declaration for its final product to be exported.
2. The applicable European Directives
So far many EU Product Directives have required the affixing of the CE marking. Among them, pneumatic components are related to the following three Directives;
- A. Directive of Machinery: Effective in Jan. 1, 1995
- This Directive prescribes the essential health and safety requirements about machinery.
- B. Directive of Electromagnetic Compatibility(EMC): Effective in Jan. 1, 1996
- This Directive applies to the products which generates electromagnetic waves or are functionally damaged by them, for example, domestic appliances, refrigerators, motors, etc.
- C. Directive of Low Voltage Electrical Equipment: Effective in Jan. 1, 1997
- This prescribes the electric safety requirements about the products used in the ranges of 50 to 1000VAC and 75 to 15000VDC
3. Koganei CE certification procedure
Koganei has obtained COC (Certificate of Conformity) which proves conformity to European EN standards about various solenoid valves and sensor switches through an Authorized Certification Body of the EU, TUV Rheinland Japan.
When you want to hold the CE Marking for your equipments or products which use Koganei solenoid valves or sensor switches as components, it would be greatly advantageous in the conformity assessment procedure.
4. List of Koganei products conforming to the European standards (as of April 1st 2016)
4-1. Solenoid valves
Depending on the specification and order code of the certificated product, it may not conform to the European standards. Only for G010 series and Micro 3-port Solenoid Valve 005 Series , “–VD” will be necessary at the end of the order code to conform to the European standards.
If you have any questions about the certificated products, please contact your nearest Koganei sales office.
Series Number |
Models Number |
Voltage | Requirements Relating to Machinery Directive |
Low Voltage Directive | ||
---|---|---|---|---|---|---|
Adaptation Standard |
Certificate Number |
Harmonized Standard |
Certificate Number |
|||
Micro 3-port Solenoid Valve 005 Series |
A005, B005, 005M |
24V DC | DIN VDE0580 | R50302510 | DIN VDE 0580 | Out of scope |
G010 | (G, GA, GV, GAV)010, G010M, G010MH |
5V DC 6V DC 12V DC 24V DC |
R50174743 | Out of scope | ||
030 | (V)030, YM | 12V DC 24V DC 100V AC 200V AC |
R09551564 | AN 965009201 | ||
040 | (A)040, (A)041, 040M, 041M |
5V DC 6V DC 12V DC 24V DC |
R09551563 | Out of scope | ||
050 | (V)050, SM | 24V DC 100V AC 200V AC |
R09250095 | AN 975051701 | ||
110 | (A)110, (A)111, (A)113, 110M, 111M |
12V DC 24V DC 100V AC 200V AC |
R09551564 | AN 965009201 | ||
112 | (A, AV, V)112, 112M |
12V DC 24V DC 100V AC 200V AC |
R09551564 | AN 965009201 | ||
180 | (A)180, (A)181, (A)183, 180M, 181M |
12V DC 24V DC 100V AC 200V AC |
R09551564 | AN 965009201 | ||
182 | (A, AV, V)182, 182M |
12V DC 24V DC 100V AC 200V AC |
R09551564 | AN 965009201 | ||
100 | (A, M, V, MV, SV, MSV)100, HM |
24V DC 100V AC 200V AC |
R09551565 | AN 965013001 | ||
200 | (A, M, V, MV, SV, MSV)200, (A)203, BM |
24V DC 100V AC 200V AC |
R09250150 | AN 975051801 | ||
F | F10T, F10LT, F15T, F15LT, F18 |
12V DC 24V DC 100V AC |
R09551566 | AN 965013101 | ||
F10M, F15M, F18M |
12V DC 24V DC 100V AC |
R09551571 | AN 965013601 | |||
JA | JA10, JA10L, JAM |
12V DC 24V DC |
R50084030 | Out of scope | ||
240 | (A, W)240, (A, W)243 |
24V DC 100V AC 200V AC |
R09551567 | AN 965013201 | ||
240M | 24V DC 100V AC 200V AC |
R09551575 | AN 965013901 | |||
300 | (A, W)300, (A)303, FM |
24V DC 100V AC 200V AC |
R09551568 | AN 965013301 | ||
350 | (A, VP)350, (A, VP)353, 350M |
24V DC 100V AC 200V AC |
R09551567 | AN 965013201 | ||
430 | 430, 432, 433 |
24V DC 100V AC 200V AC |
R09551569 | AN 965013401 | ||
430M, 432M | R09551574 | AN 965013801 | ||||
630 | 630, 632, 633 |
24V DC 100V AC 200V AC |
R09551569 | AN 965013401 | ||
630M, 632M | R09551574 | AN 965013801 | ||||
830 | 830, 833 | 24V DC 100V AC 200V AC |
R09551569 | AN 965013401 | ||
062 | (V, SV)062, MM |
6V DC 12V DC 24V DC 48V DC 100V AC 110V AC 115V AC 200V AC 220V AC 230V AC |
R09551570 | AN 965013501 | ||
125 | 125, MM | 6V DC 12V DC 24V DC 100V AC 200V AC |
||||
126 | (V)126, MM | |||||
250 | (VA, VV)250, (VA, VV)2503 |
6V DC 12V DC 24V DC 100V AC 110V AC 115V AC 200V AC 220V AC 230V AC |
||||
253 | 253 | |||||
254 | 254, M | |||||
500 | (VA, VV)500 | |||||
375 501 | 375, 501 | |||||
503 | 503 | |||||
750 | 750 | |||||
753 | 753 | |||||
1000 1250 |
1000, 1250 | |||||
X80M | FMCR, FMWR, F1WR |
12V DC 24V DC |
R09551572 | Out of scope | ||
X88M | FMC, FMW, FMX, FMY |
12V DC 24V DC 100V AC 200V AC |
R09551573 | AN965014001 |
4-2. Sensor switches
Depending on the specification and order code of the certificated product, it may not conform to the European standards.
Series Number |
Models Number |
Requirements Relating to EMC Directive |
Requirements Relating to Machinery Directive |
Low Voltage Directive | |||
---|---|---|---|---|---|---|---|
Harmonized Standard |
Certificate Number |
Adaptation Standard |
Certificate Number |
Harmonized Standard |
Certificate Number |
||
Reed sensor switch |
CS5T CS11T ZC201 ZC205 ZC301 ZC305 ZC601 ZC605 CS3H CS4H CS5H CS3M CS4M CS5M ZE101 ZE102 ZE201 ZE202 |
EN61000- 6-2 EN61000- 6-4 |
CC9750876 | EN62246-1 | R09750858 | EN62246-1 | AN 50125574 |
Solid state sensor switch |
ZC130 ZC153 ZC230 ZC253 ZC330 ZC353 ZC630 ZC653 ZE135 ZE155 ZE235 ZE255 ZG530 ZG553 ZD136 CS9H |
EN61000- 6-2 EN61000- 6-4 EN60947- 5-2 |
CC9750885 | Out of scope | Out of scope |